Work procedure
- Connect diagnostic tester. See Connect diagnostic tester .
- Start engine and let run at idle for at least 15 minutes.
- In diagnostic function "33 - OBD", select "Mode 6: Check test results of components that are not continuously monitored".
- Select the "Test-ID 03: Secondary Air Injection (AIR) system"
- Check specified values at idle.SECONDARY AIR INJECTION (AIR) SYSTEM SPECIFICATION
Secondary Air Injection (AIR) system Specification (1) - Bank 1
min: 24,000 (1) Control module internal calculated value - End diagnosis and switch ignition off.
If the specified values are not reached:
- Check secondary air system for proper seal. See SECONDARY AIR INJECTION (AIR) SYSTEM, CHECKING FOR PROPER SEAL .
- Check Secondary Air Injection (AIR) Pump Motor -V101-. See CHECK VOLTAGE SUPPLY OF THE SECONDARY AIR INJECTION (AIR) PUMP MOTOR .