Control module and output signals
WARNING: This page is about a different variant/trim than selected.
| DTC | Error Message | Diagnostic Procedure | Malfunction Criteria and Threshold Value | Secondary Parameters with Enable Conditions | Monitoring Time Length | Frequency of checks, MIL Illumination |
|---|---|---|---|---|---|---|
| P0601 | Internal Control Module Memory Check Sum Error |
|
Internal check sum, incorrect | 0.5 Seconds |
|
|
| P0604 | Internal Control Module Random Access Memory (RAM) Error |
|
Write ability check, failed | 0.5 Seconds |
|
|
| P0605 | Internal Control Module Read Only Memory (ROM) Error |
|
Check, failed | 0.5 Seconds |
|
|
| P0606 | ECM/PCM Processor |
|
|
|
25 Seconds Cont 2 Seconds |
|
| P0638 | Throttle Actuator Control Range/Performance - Bank 1 |
|
|
|
10 Seconds |
|
| P0685 | ECM/PCM Power Relay Control Circuit/Open |
|
Open circuit | 0.5 Seconds |
|
|
| P0686 | ECM/PCM Power Relay Control Circuit Low |
|
Short to ground | 0.5 Seconds |
|
|
| P0687 | ECM/PCM Power Relay Control Circuit High |
|
Short to battery + | 0.5 Seconds |
|