Test-B: Oxygen Sensor Behind Catalytic Converter Bank 2- Sensor 2
WARNING: This page is about a different car, the 2006 Audi TT, 2005 Audi TT, and 2004 Audi TT. However, it is still accessible from the selected car via links, so may be relevant.
- Connect the scan tool.
- Start the engine and let run at idle speed.
- Select "Mode 6: Check test the results of components that are not continuously monitored".
Select "Test-B".
- Select the desired "Test-ID".
- Check specified values at idle.
| Test-ID (TID) (Hex-ID) | DTC | Component or System | Min. | Max. | Additional Information |
|---|---|---|---|---|---|
| 01 ($01) | Voltage barrier from rich to lean (fixed value). | ||||
| 02 ($02) | Voltage barrier from lean to rich (fixed value). | ||||
| 07 ($07) | Minimum oxygen sensor voltage value in this driving cycle. | 30 mV | 400 mV | ||
| 08($08) | Maximum sensor voltage value in this driving cycle. | 500 mV | 1075 mV |
- If any component or system fails to meet the specified values, refer to Diagnostic "Mode 03: Interrogating Fault Memory" to check for stored DTCs or the corresponding diagnostic repair procedure.
- Switch the ignition off.
End of diagnosis.