A/C refrigerant system, checking pressures: Checking
- - Switch ignition off.
- - Connect high pressure hose of refrigerant recovery/recycling/recharging unit Kent-Moore ACR4 , or equivalent, to high pressure service connection. See DISCHARGING .
- - Leave low pressure hose of refrigerant recovery/recycling/recharging unit disconnected.
NOTE:
Only the high pressure service valve is used for A/C system servicing. Perform all A/C system service operations (i.e. discharging, evacuating and charging) through the high pressure service valve only.
OUTSIDE TEMPERATURE VERSUS A/C REFRIGERANT PRESSURES
| Outside (ambient) temperature (1) | Base pressure in refrigerant system (engine OFF) | ||
|---|---|---|---|
| +15° C (59° F) | 3.9 bar (56.5 psi) | ||
| +20° C (68° F) | 4.7 bar (68.2 psi) | ||
| +25° C (77° F) | 5.6 bar (81.2 psi) | ||
| +30° C (86° F) | 6.7 bar (97.2 psi) | ||
| +35° C (95° F) | 7.8 bar (113.1 psi) | ||
| +40° C (104° F) | 9.1 bar (132.0 psi) | ||
| +45° C (113° F) | 10.5 bar (152.3 psi) | ||
|
|||