Function test
- Connect diagnostic tester. See DIAGNOSTIC TESTER, CONNECTING .
- Start engine and let run at idle for at least 15 minutes.
- Under address word 33, select "Diagnostic mode 8: Tank leak test".
- Select measuring value "Test-ID 01: Tank leak test".
- Check specified value of tank leak test at idle.
TEST-ID 01: TANK LEAK TEST
| Test-ID 01: | Tank leak test | Specified value: |
|---|---|---|
|
Test OK | |
| No results |
NOTE:
- The function test can take a few minutes.
- If the accelerator pedal is depressed during the test, the test will be aborted.
- To repeat the tank leak test, switch ignition off and start engine again and let run at idle for at least 15 minutes.
If specified value is obtained:
- End diagnosis and switch ignition off.
If specified value is not obtained:
- EVAP canister system, checking for proper seal. See EVAP CANISTER SYSTEM, CHECKING FOR PROPER SEAL .
- Leak detection pump (LDP) -V144-. For checking, see LEAK DETECTION PUMP (LDP), CHECKING .