LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 1999 >> A6 Base >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generators & Regulators >> On-Vehicle Testing >> Generator Exciter Circuit Tests >> Resistance Test

Resistance Test

Disconnect negative battery cable. Disconnect Blue (D+) wire from generator. Connect ohmmeter leads between Blue wire and battery positive terminal. Turn ignition on. Resistance should be 140-160 ohms. If resistance is not 140-160 ohms, check generator bulb. If bulb is okay, replace instrument cluster printed circuit and retest.