Safety Lockout Switch
Remove safety lockout switch and disconnect harness connector. Check continuity between switch terminals with switch in appropriate position. Refer to the SAFETY LOCKOUT SWITCH TEST . See Fig 1 . If continuity is not as specified, replace safety lockout switch.
SAFETY LOCKOUT SWITCH TEST
| Switch Position | Between Terminals No. | Specification |
|---|---|---|
| Off | 1 & 2 | No Continuity |
| " | 3 & 4 | No Continuity |
| On | 1 & 2 | Continuity |
| " | 3 & 4 | Continuity |