Lower Chamber Pressure-Part I
- Close valve on pressure gauge. Turn on jumper (US 4480/3). Plug to differential pressure regulator must be unplugged. Differential pressure must be 2.9-7.0 psi (.2-.5 kg/cm2 ) less than measured system pressure.
- Disconnect lower chamber return line from diaphragm pressure regulator and hold over measuring container. Plug open connection to diaphragm pressure regulator. Turn on Jumper (US 4480/3) for 1 minute. Fuel flow must be 130-150 cc/minute.
- If flow quantity is correct, replace differential pressure regulator. If flow quantity is not correct, replace fuel distributor.