Control Switch Continuity
Disconnect 4-wire connector from control switch. Connect a jumper wire from a 12-volt source to the Red wire in the connector. Use a 12-volt test light to check for continuity in switch. Connect one end to ground, then touch probe to switch connector terminals. Light should glow as indicated in CONTROL SWITCH CONTINUITY .
CONTROL SWITCH CONTINUITY
| Switch Position | Terminals with Power |
|---|---|
| "OFF" | None |
| "ON" | Green, Brown |
| "RESUME/ACCEL" | All |
| BUTTON PRESSED | Yellow, Brown |