Removal And Installation: 2.0L
REMOVAL
- Disconnect and isolate the negative battery cable.
- Remove the air cleaner assembly. Refer to BODY, AIR CLEANER, REMOVAL AND INSTALLATION .
- Remove the serpentine belt. Refer to REMOVAL AND INSTALLATION, BELT, SERPENTINE
- Remove the terminal cover (1).
- Disconnect the wiring harness connector (2) from the generator.
- Remove the generator retaining bolts (1b).
- Remove the generator (1b).
INSTALLATION
- Inspect the generator and wiring harness connector integrity before positioning the generator for installation.
- Install and tighten the generator (1a) retaining bolts (1b) to the proper specification. Refer to TECHNICAL SPECIFICATIONS .
- Connect the wiring harness connector to the generator.
- Using a nut, connect and secure the B+ to the generator.
- Install the terminal cover.
- Install the serpentine belt. Refer to BELT, SERPENTINE, REMOVAL AND INSTALLATION .
- Install the air cleaner assembly. Refer to BODY, AIR CLEANER, REMOVAL AND INSTALLATION .
- Connect the negative battery cable and perform the Powertrain Verification Test. Refer to POWERTRAIN VERIFICATION TEST .