LEMON Manuals: Even more car manuals for everyone
Home >> Alfa Romeo >> 2016 >> 4C Base >> Repair and Diagnosis >> Engine Performance >> System >> 1.8L - DTCS P000A-00 To P0481-00 >> DTC Troubleshooting >> P0138-00-O2 Sensor 1/2 Circuit High >> Diagnostic Test

Diagnostic Test

  1. CHECK FOR AN ACTIVE DTC 
    1. With the scan tool, read DTCs.

      Is the DTC active?

      Yes 

      • Go To  2

      No 

      • Test complete.
  2. CHECK CONNECTIONS FOR POWERTRAIN CONTROL MODULE AND O2 SENSOR 
    1. Check for the presence of loose electrical connections at the Powertrain Control Module and the O2 Sensor.

      Were any loose electrical connections present?

      Yes 

      • Restore the correct connections.

      No 

      • Go To  3
  3. CHECK THE O2 SENSOR WIRING CONTINUITY 
    1. Check the correct continuity of the wiring between the O2 Sensor and the Powertrain Control Module.

      Does the wiring have continuity?

      Yes 

      • Go To  4

      No 

      • Restore the correct continuity for the wiring.
  4. CHECK THE O2 SENSOR GROUND WIRING CONTINUITY 
    1. Check the correct continuity of the wiring between the O2 Sensor and the Powertrain Control Module.

      Does the wiring have continuity?

      Yes 

      • Go To  5

      No 

      • Restore the correct continuity for the wiring.
  5. CHECK O2 SENSOR WIRING FOR A SHORT TO BATTERY 
    1. Check the correct insulation of the wiring between Battery and the O2 Sensor.

      Was the wiring shorted to Battery?

      Yes 

      • Restore the correct insulation for the wiring.

      No 

      • Go To  6
  6. CHECK ON SEEPAGE IN EXHAUST MANIFOLD 
    1. Check for the presence of any seepage in the Exhaust Manifold.

      Seepage inside the Exhaust Manifold?

      Yes 

      • Restore correct operation.

      No 

      • Go To  7
  7. O2 SENSOR CONDITION CHECK 
    1. Check for the presence of any oil or oxidation on the sensitive element or damage to the sensor casing.

      Sensor fouled or contaminated?

      Yes 

      • Clean the O2 Sensor.

      No 

      • Go To  8
  8. CHECK OXYGEN SENSOR FITTING 
    1. Check for proper fitting of the O2 Sensor.

      Is the O2 Sensor fitted properly?

      Yes 

      • Restore the correct fitting of the O2 Sensor.

      No 

      • Go To  9
  9. CHECK OPERATION OF THE OXYGEN SENSOR 
    1. Check that the O2 Sensor is working properly.

      Is the O2 Sensor working properly?

      Yes 

      • End of diagnosis.

      No