Home >> Acura >> 2023 >> MDX Base >> Repair and Diagnosis >> Steering >> Steering Control Systems >> Body Electrical System - Troubleshooting - System Description >> Troubleshooting >> Keyless/Power Door Locks/Security System Symptom Troubleshooting - Security alarm system will not arm >> HOOD_SW, HOOD_SW2, SGND Circuit Inspection

HOOD_SW, HOOD_SW2, SGND Circuit Inspection

Test Procedure 

(Disconnected) Left hood latch switch 2P connector female terminals

(Disconnected)Relay control module connector C (18P) female terminals

IG Mode

GHH659433Courtesy of HONDA, U.S.A., INC.
GHH659434Courtesy of HONDA, U.S.A., INC.

Normal Conditions

HOOD_SW open wire inspection 

OFF

There is less than 1 Ohm 

Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.

HOOD_SW shorted to ground inspection 

OFF

Not shorted 

(Disconnected) Right hood latch switch 2P connector female terminals

(Disconnected) Left hood latch switch 2P connector female terminals

IG Mode

GHH659435Courtesy of HONDA, U.S.A., INC.
GHH659436Courtesy of HONDA, U.S.A., INC.

Normal Conditions

HOOD_SW2 open wire inspection 

OFF

There is less than 1 Ohm 

SGND open wire inspection 

OFF

There is less than 1 Ohm 

Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.

HOOD_SW2 shorted to ground inspection 

OFF

Not shorted 

Results