Audio Remote-HFL Switch Inspection
Test Procedure
- Preparation
-
- -
Audio remote-HFL switch connector (16P) : disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
- -
(Disconnected) Audio remote-HFL switch connector (16P) male terminals
IG Mode
Normal Conditions
Switch internal circuit inspection
OFF
There is less than 1 Ohm
Results
- If it is abnormal, there is a problem with the audio remote-HFL switch.