EOPVB [EOP_RLY_OUT] Shorted Wire Inspection
Test Procedure
- Preparation
-
- -
Electric oil pump connector (4P): disconnected
- -
Electric oil pump relay: disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
- -
(Disconnected) Electric oil pump connector (4P) female terminals
IG Mode
Normal Conditions
EOPVB [EOP_RLY_OUT] shorted to power inspection
ON
Not shorted
Results
- If abnormal, there is a problem in the circuit.