A/F Sensor (Sensor 1) Component Inspection
Test Procedure
- Preparation
-
- -
A/F sensor (Sensor 1) connector (6P) : disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
- -
(Disconnected) A/F sensor (Sensor 1) connector (6P) male terminals
IG Mode
Normal Conditions
Sensor internal circuit inspection
OFF
About 2.8 - 4.5 Ohm (at room temperature)
OFF*1
Not shorted
OFF*1
Not shorted
OFF*1
Not shorted
OFF*1
Not shorted
OFF*1
Not shorted
OFF
There is no continuity
OFF
There is no continuity
OFF
There is no continuity
*1: A/F sensor (Sensor 1) is installed
Results
- If it is abnormal, there is a problem with the A/F sensor (Sensor 1).