IG1_METER Open Wire Inspection
Test Procedure
- Procedure
-
- Perform the inspection according to the following table.
(Connected)Body control module connector A (66P) female terminals
IG Mode
Normal Conditions
IG1_METER open wire inspection
ON
12 V battery voltage [circuit type 1]
Results
- If it is abnormal, there is a problem in the circuit.
If the power supply inspection of the above table showed abnormally, do the additional Power Supply Inspection , to locate the failure.
- If it is normal, there is a problem with the body control module.