Component Connected to LIN (BATT_SENSOR) Circuit Inspection
NOTICE:
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Preconditions
NOTE: This procedure can be done before any other inspections are completed because this test procedure includes all of the following inspection items. However, if this test fails, it will be necessary to continue with each inspection item individually to determine which item failed.
- External circuit is normal
Test Procedure
- Preparation
-
- -
DC-DC converter connector A (3P): disconnected
- -
Alternator connector (1P): disconnected
- -
12 volt battery sensor connector (2P): disconnected
- -
PCM connector A (50P): disconnected
- -
- Procedure
Perform the inspection according to the following table and while reconnecting these connectors, one at a time:
-
- -
Alternator connector (1P)
- -
12 volt battery sensor connector (2P)
- -
PCM connector A (50P)
- -
(Disconnected)DC-DC converter connector A (3P)female terminals
IG Mode
Normal Conditions
LIN (BATT_SENSOR) shorted to parts inspection
OFF
Not shorted
Results
- If it is abnormal, there is a problem with the part that has shorted when it was reconnected.