A/C Refrigerant Recovery/Evacuation/Charging: Procedure

How to use this manual .

WARNING:
  • Compressed air mixed with the HFO-1234yf (R-1234yf) forms a combustible vapor.
  • The vapor can burn or explode causing serious injury.
  • Never use compressed air to pressure test HFO-1234yf (R-1234yf) service equipment or vehicle air conditioning systems.
WARNING:
  • Air conditioning refrigerant or lubricant vapor can irritate your eyes, nose, or throat.
  • Be careful when connecting service equipment.
  • Do not breathe refrigerant or vapor.

NOTICE: 

When an A/C System has been opened to the atmosphere, such as during installation or repair, it must be evacuated using an A/C recover/recycle/recharge machine. If the system has been open for several days, replace the receiver/dryer or the desiccant, drain the refrigerant oil - Refer to: A/C Refrigerant Oil Replacement  or A/C Refrigerant Oil Adjustment , and add fresh oil. Then evacuate the system for several hours before charging it.

  1. A/C Refrigerant - Recover

    Procedure 

    1. Recover the refrigerant from the A/C system.

    2. Measure the amount of refrigerant oil - Refer to: A/C Refrigerant Oil Replacement  or A/C Refrigerant Oil Adjustment 

    removed from the A/C system after the recovery process is completed. Be sure to put the same amount of new refrigerant oil - Refer to: A/C Refrigerant Oil Replacement  or A/C Refrigerant Oil Adjustment  back into the A/C system before charging.

     
  2. A/C System - Evacuate

    Procedure/Specifications 

    1. Evacuate the system. The vacuum pump should run for a minimum of 30 minutes or until the moisture vacuum test passes, to eliminate all moisture from the system. When the suction gauge reads -93.3 kPa (-700 mmHg, -27.55 inHg) for at least 30 minutes, or the moisture vacuum test passes, close all valves, and turn off the vacuum pump.

    2. If the suction gauge does not reach approximately -93.3 kPa (-700 mmHg, -27.55 inHg) in 15 minutes, the moisture vacuum test fails, there is probably a leak in the system. Partially charge the system, and check for leaks.

     
  3. A/C Refrigerant - Charge

    Procedure/Specifications 

    • Charge the system with the specified amount. Do not overcharge the system; the A/C compressor will be damaged.

    Select the appropriate units of measure for your refrigerant A/C recover/recycle/recharge machine.

    Refrigerant Capacity 

    Type Specified Amount
    HFO-1234yf (R-1234yf) 505 to 555 g
    17.81 to 19.58 oz
    0.505 to 0.555 kg
    1.113 to 1.224 lbs

    After Charging