LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2021 >> TLX Base >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Keyless Access Power Control Unit - Diagnostics >> DTC Troubleshooting >> DTC B12C5 >> Inspection

DTC B12C5: Inspection

+B_SMART, SS1(+), SS2(-), GND Circuit Inspection 

Test Procedure 

           
      (Disconnected) Engine start/stop switch 10P connector female terminals (Disconnected)Body control module connector G (32P) female terminals  
    IG Mode
GHH485146Courtesy of HONDA, U.S.A., INC.

GHH485147Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  +B_SMART circuit inspection  OFF   12 V battery voltage[circuit type 1] 
  SS1(+) open wire inspection  OFF There is less than 1 Ohm 
  SS2(-) open wire inspection  OFF There is less than 1 Ohm 
  GND open wire inspection  OFF   There is less than 1 Ohm 
  NOTE: Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  SS1(+) shorted to ground inspection  OFF   Not shorted 
  SS2(-) shorted to ground inspection  OFF   Not shorted 

Results 

Body Control Module Inspection 

Test Procedure 

Results