PCM Inspection
Preconditions
NOTE:
This procedure can be done before any other inspections are completed because this test procedure includes all of the following inspection items. However, if this test fails, it will be necessary to continue with each inspection item individually to determine which item failed.
- External circuit is normal
Test Procedure
- Preparation
- A/F sensor (Sensor 1) connector 6P : disconnected
- Procedure
Results
- If it is abnormal, there is a problem in the PCM.