Power Window Master Switch Connector for Inputs and Outputs

Power Window Master Switch 37P Connector (female terminals) 

GHH339115Courtesy of HONDA, U.S.A., INC.
POWER WINDOW MASTER SWITCH 37P CONNECTOR INDEX

Terminal number Terminal name Description Signal
1 P/W_DR_MTR_DOWN Drives driver's power window motor With driver's power window motor DOWN operation: about battery voltage If none of the above conditions are met: less than 0.2 V
2 P/W_DR_MTR_UP Drives driver's power window motor With driver's power window motor UP operation: about battery voltage If none of the above conditions are met: less than 0.2 V
3 PGND Ground for power window master switch Less than 0.2 V at all times
4 +B_DR_P/W (20A) Power source for power window master switch About battery voltage at all times
5 DR_MEMORY_SEAT_SW_POS1 Detects DR_MEMORY_SEAT_SW_POS1 signal With driving position memory switch 1 ON: less than 0.2 V With driving position memory switch 1 OFF: about battery voltage
6 DR_MEMORY_SEAT_SW_POS2 Detects DR_MEMORY_SEAT_SW_POS2 signal With driving position memory switch 2 ON: less than 0.2 V With driving position memory switch 2 OFF: about battery voltage
7 DR_KEY_CYL_LOCK Detects DR_KEY_CYL_LOCK signal With driver's door key cylinder switch LOCK: less than 0.2 V If none of the above condition are met: about battery voltage
8 DR_KEY_CYL_UNLOCK Detects DR_KEY_CYL_UNLOCK signal With driver's door key cylinder switch UNLOCK: less than 0.2 V If none of the above condition are met: about battery voltage
9 Not used --- ---
10 Not used --- ---
11 Not used --- ---
12 Not used --- ---
13 Not used --- ---
14 Not used --- ---
15 H/MIRROR_DR Outputs H/MIRROR_DR signal With mirror defogger ON: about battery voltage
16 DR_MEM_SEAT_SW_GND Ground for driving position memory switch With door multiplex control unit is wake up mode: less than 0.2 V
17 DR_MEMORY_SEAT_SW_MEMORY Detects DR_MEMORY_SEAT_SW_MEMORY signal With driving position memory set switch ON: less than 0.2 V With driving position memory set switch OFF: about battery voltage
18 IG2_OPTION IG2 power source With the vehicle in the ON mode: about battery voltage
19 Not used --- ---
20 DR_SIL_UNLOCK Detects DR_SIL_UNLOCK signal With door multiplex control unit is wake up mode and driver's door lock knob switch LOCK: about 5 V With driver's door lock knob switch UNLOCK: less than 0.2 V
21 DR_SIL_LOCK Detects DR_SIL_LOCK signal With door multiplex control unit is wake up mode and driver's door lock knob switch UNLOCK: about 5 V with driver's door lock knob switch LOCK: less than 0.2 V
22 DR_MEMORY_SEAT_SW_IND1 Outputs DR_MEMORY_SEAT_SW_IND1 signal Driving position memory switch indicator 1 ON: pulse (depending on indicator brightness) Driving position memory switch indicator 1 OFF: less than 0.2 V
23 * RETRA_MIRROR_SW Detects RETRA_MIRROR_SW signal With the vehicle in the ON mode and power mirror retract switch in EXTEND position: less than 0.2 V With the vehicle in the ON mode, and power mirror retract switch in RETRACT position: about battery voltage
24 DR_MEMORY_SEAT_SW_IND2 Outputs DR_MEMORY_SEAT_SW_IND2 signal Driving position memory switch indicator 2 ON: pulse (depending on indicator brightness) Driving position memory switch indicator 2 OFF: less than 0.2 V
25 Not used --- ---
26 Not used --- ---
27 * DR_RETRA_OPEN Drives retract actuator With the vehicle in the ON mode, and power mirror EXTEND operation: about battery voltage If none of the above conditions are met: less than 0.2 V
28 * RETRA_CLOSE Drives retract actuator With the vehicle in the ON mode, and power mirror RETRACT operation: about battery voltage If none of the above conditions are met: less than 0.2 V
29 GND Ground for power window master switch Less than 0.2 V at all times
30 P/W_SW_ILLUMI Outputs P/W_SW_ILLUMI signal With combination light switch PARKING: about battery voltage With combination light switch OFF: less than 0.2 V
31 B-CAN_L Communication line ---
32 B-CAN_H Communication line ---
33 P/W_DR_MTR_PLSA Detects P/W_DR_MTR_PLSA signal ---
34 P/W_DR_MTR_VCC Outputs P/W_DR_MTR_VCC signal With door multiplex control unit is wake up mode and driver's power window motor operation: about battery voltage If none of the above conditions are met: less than 0.2 V
35 P/W_DR_MTR_PLSB Detects P/W_DR_MTR_PLSB signal ---
36 LIN (P/W) Communication line ---
37 +B_BACK_UP Power source for power window master switch About battery voltage at all times
*: With power retract mirror