DTC P2841: Shift Fork D Position Circuit (Range) (DCT)

General Description 

GHH159199Courtesy of HONDA, U.S.A., INC.

The shift fork D position sensor detects the stroke amount of 6-8 shift fork according to the output voltage. The powertrain control module (PCM) sends a 5 V reference signal to the sensor through a pull-up resistor. The shift fork D position sensor outputs a voltage of about 1 V when the 8th gear is engaged, about 4 V when the 6th gear is engaged, and about 2.5 V when it is in neutral position. If the shift fork D position sensor output voltage is in a specified range for a specified duration, the PCM detects a malfunction and stores a DTC.

Monitor Execution, Sequence, Duration, DTC Type, OBD Status 

Execution Continuous
Sequence None
Duration 1 second or more
DTC Type One drive cycle, MIL on, A/T gear position indicator blinks
OBD Status PASSED/FAILED/NOT COMPLETED (STILL TESTING)

Enable Conditions 

Condition  
Vehicle ON mode
No active DTCs set (prevents monitor from running) P2842, P2843

Malfunction Threshold 

The shift fork D position sensor output voltage [Stroke sensor D voltage.] is between 0.205 V to 0.387 V or 4.632 V to 4.921 V for at least 1 second.

[ ]: HDS Parameter

Possible Cause 

NOTE:  The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.

Confirmation Procedure 

Operating Condition 

Start the engine in P position/mode, and wait for at least 1 second.

With the HDS 

None.

Diagnosis Details 

Conditions for setting the DTC 

When a malfunction is detected, the MIL comes on and a Pending DTC, a Confirmed DTC, and the freeze data are stored in the PCM memory.

Conditions for clearing the DTC 

The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the 12 volt battery.