Malfunction Threshold
One of these conditions occurs:
- The PCM detects the selected position signal input and another position signal input simultaneously for at least 1 second.
- The PCM detects the P, R, or N position signal input and the FWD position signal input simultaneously for at least 1 second.
- The PCM detects the D or S position signal input and the RVS position signal input simultaneously for at least 1 second.