Power Supply

Battery voltage is supplied at all times to the Driver's MICU, the Passenger's MICU, and the Power Window Master Switch through fuse 15 (in the under-hood fuse/relay box). Battery voltage is also supplied at all times to the Power Window Master Switch through fuse 24 (in the driver's under-dash fuse/relay box) and to the Front Passenger's Power Window Switch through fuse 13 (in the passenger's under-dash fuse/relay box). With the ignition switch in ON (II) or START (III) or the engine start/stop switch in ON or START mode, battery voltage is supplied to the Driver's MICU and the Passenger's MICU through fuse 12 (in the driver's under-dash fuse/relay box). With the ignition switch in ON (II) or the engine start/stop switch in the ON mode, battery voltage is supplied to the Power Window Master Switch through fuse 16 (in the driver's under-dash fuse/relay box).