Recirculation Control Motor Replacement
WARNING: This page is about a different car, the 2008 Acura TSX, 2007 Acura TSX, 2006 Acura TSX, 2005 Acura TSX, and 2004 Acura TSX. However, it is still accessible from the selected car via links, so may be relevant.
- Open the glove box. Remove the damper from the glove box, then let the glove box hang down (see GLOVE BOX REMOVAL/INSTALLATION ).
- Remove the relays from the bracket.
- Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor from the blower unit.
- Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.