LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2009 >> TSX Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 17 (Automatic HVAC System) >> Climate Control >> Mode Control Motor Replacement

Mode Control Motor Replacement

WARNING: This page is about a different car, the 2008 Acura TSX, 2007 Acura TSX, 2006 Acura TSX, 2005 Acura TSX, and 2004 Acura TSX. However, it is still accessible from the selected car via links, so may be relevant.
  1. Open the glove box. Remove the damper from the glove box, then let the glove box hang down (see GLOVE BOX REMOVAL/INSTALLATION ).
  2. Remove the relays from the bracket.
    Fig 1: Identifying Relays Of Bracket
    G05492679Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Disconnect the 7P connector (A) from the mode control motor (B). Remove the self-tapping screws and the mode control motor from the heater unit.
    Fig 2: Identifying 7P Connector And Mode Control Motor
    G05492680Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Install the motor in the reverse order of removal. After installation, make sure the motor runs smoothly.