Blower Unit Removal/Installation

WARNING: This page is about a different car, the 2008 Acura TSX, 2007 Acura TSX, 2006 Acura TSX, 2005 Acura TSX, and 2004 Acura TSX. However, it is still accessible from the selected car via links, so may be relevant.
  1. Remove the following items:
  2. Remove the wire harness connector clips (A), the wire harness clip (B), and bolt. Cut the plastic cross brace (C) in the glove box opening with diagonal cutters in the area shown.
    Fig 1: Identifying Wire Harness Connector Clips, Wire Harness Clip And Bolt
    G05492686Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Disconnect the connectors (A) from the blower motor, the floor wire harness, and the recirculation control motor, then remove the wire farness clips (B) and the connector clip (C). Remove the mounting nuts, the mounting bolts and the blower unit (D).
    Fig 2: Blower Unit Mounting Nuts And Bolts W/Torque Specifications
    G05492687Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Install the unit in the reverse order of removal. Make sure that there is no air leakage.