Pressure retaining mode

VSA NO valve closed, VSA NC valve open, inlet valve closed, outlet valve closed, pump motor ON.

The front and rear caliper fluid is retained by the inlet valve and the outlet valve.

Fig 1: VSA System Circuit Diagram (Pressure Retaining Mode)
G06160437Courtesy of AMERICAN HONDA MOTOR CO., INC.