EVAP Canister Replacement
- Disconnect the hoses (A), the FTP sensor 3P connector (B), and the EVAP canister vent shut valve 2P connector (C).
- Remove the EVAP canister assembly (D).
- Remove the EVAP canister bracket (A) and the EVAP canister cover (B) from the EVAP canister (C).
- Install the parts in the reverse order of removal.