LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2009 >> CSX Base, Automatic >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC >> Climate Control >> Recirculation Control Motor Replacement

Recirculation Control Motor Replacement

  1. Remove the glove box (see PASSENGER'S DASHBOARD UNDERCOVER REMOVAL/INSTALLATION ) and the kick panel (see TRIM REMOVAL/INSTALLATION - DOOR AREAS ).
  2. Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self- tapping screws and the recirculation control motor from the blower unit.
    Fig 1: Identifying 7P Connector From Recirculation Control Motor
    G06269175Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.