Malfunction Threshold
Either of these conditions is met.
- The estimated volume of intake air is 140 l/min (148.0 US qt/min, 123.2 lmp qt/min)*1, 300 l/min (317.1 US qt/min, 264.0 lmp qt/min)*2 or more when the MAP value is 35 kPa (10.3 in.Hg, 260 mmHg)*2, 47 kPa (13.8 in.Hg, 350 mmHg)*1 .
- The estimated volume of intake air is 130 l/min (137.4 US qt/min, 114.4 lmp qt/min)*1 , 300 l/min (317.1 US qt/min, 264.0 lmp qt/min)*2 or more when the MAP value is 48 kPa (14.2 in.Hg, 360 mmHg)*2 , 58 kPa (17.0 in.Hg, 430 mmHg)*1 .
*1: J32A3 engine
*2: J35A8 engine