ODS Unit Calibration

WARNING: This page is about a different car, the 2008 Acura TL and 2007 Acura TL. However, it is still accessible from the selected car via links, so may be relevant.

When you replace the SRS unit, front passenger's weight sensors or ODS unit, calibrate the ODS unit.

While calibrating the ODS unit, observe these precautions:

  1. Position the front passenger's seat to the rearmost position, and adjust the recliner to the forward most position. Do not move the seat from this position.
  2. Make sure the ignition switch is OFF.
  3. Connect the HDS to the data link connector (DLC) (A).
    Fig 1: Identifying HDS To Data Link Connector (DLC)
    G05463380Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Turn the ignition switch ON (II).
  5. Make sure the HDS communicates with the vehicle and the SRS unit. If it does not communicate, troubleshoot the DLC circuit (see DLC CIRCUIT TROUBLESHOOTING (PART 2) ).
  6. Drive the vehicle, and accelerate to 20 mph (36 km/h), then stop on level ground.
  7. From the Main Menu, select SRS, then Calibration, then Misc Test, then select "SWS INITIALIZATION," and follow the prompts until the calibration has been completed.