LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2007 >> RL >> Repair and Diagnosis >> Brakes >> Traction Control >> VSA (Vehicle Stability Assist) System >> System Description >> VSA Control >> Pressure retaining mode

Pressure retaining mode

VSA NO valve closed, VSA NC valve open, inlet valve closed, outlet valve closed, pump motor ON.

Front and rear caliper fluid is retained by the inlet valve and outlet valve.

Fig 1: VSA System Diagram (Pressure Retaining Mode)
G05498593Courtesy of AMERICAN HONDA MOTOR CO., INC.