LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2007 >> RL >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Keyless Access System >> DTC Troubleshooting >> DTC B1675: Ignition Switch Control Unit (ROTATE SW) Circuit Open

DTC B1675: Ignition Switch Control Unit (ROTATE SW) Circuit Open

  1. Clear the DTCs with the HDS.
  2. Turn the ignition switch OFF.
  3. Insert the built-in key into the ignition switch.
  4. Turn the ignition switch ON (II) and OFF ten times using the built-in key.
  5. Check for DTCs with the HDS.

    Is DTC B1675 indicated? 

    YES  - Go to step 6.

    NO  - Intermittent failure, the system is OK at this time. Check for loose or poor connections at the keyless access control unit and at the ignition switch control unit.

  6. Turn the ignition switch OFF.
  7. Disconnect keyless access control unit connector A (31P).
  8. Disconnect the ignition switch control unit 10P connector.
  9. Check for continuity between keyless access control unit connector A (31P) terminal No. 3 and ignition switch control unit 10P connector terminal No. 8.
    Fig 1: Checking Continuity Between Terminal No. 3 And Ignition Switch Control Unit 10P Connector Terminal No. 8
    G05497411Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there continuity? 

    YES  - Go to step 10.

    NO  - Repair an open in the wire.

  10. Turn the ignition switch to the ACC (I) position.
  11. Check for continuity between ignition switch control unit 10P connector terminals No. 8 and No. 6.
    Fig 2: Checking Continuity Between Ignition Switch Control Unit 10P Connector Terminals No. 8 And No. 6
    G05497412Courtesy of AMERICAN HONDA MOTOR CO., INC.

    Is there continuity? 

    YES  - Replace the keyless access control unit.

    NO  - Replace the ignition switch control unit.