Door Key Cylinder Switch Test
WARNING: This page is about a different car, the 2011 Acura TL, 2010 Acura TL, and 2009 Acura TL. However, it is still accessible from the selected car via links, so may be relevant.
- Remove the driver's door panel (see FRONT DOOR PANEL REMOVAL/INSTALLATION )
- Disconnect the 10P connector (A) from the door lock actuator (key cylinder switch) (B)
- Check for continuity between the terminals
- There should be continuity between terminals No 9 and No 5 when the door key cylinder switch is in LOCK position
- There should be no continuity between terminals No 9 and No 5 when the door key cylinder switch is in the neutral or UNLOCK position
- There should be continuity between terminals No 8 and No 5 when the door key cylinder switch is in UNLOCK position
- There should be no continuity between terminals No 8 and No 5 when the door key cylinder switch is in the neutral or LOCK position
- There should be no continuity between terminals No 8 and No 9 when the key is in the neutral position
- If the continuity is not as specified, the switch is faulty; replace the door latch (see FRONT DOOR LATCH REPLACEMENT )