Pressure Retaining Mode

VSA NO valve closed, VSA NC valve open, inlet valve closed, outlet valve closed, pump motor ON.

Front and rear caliper fluid is retained by the inlet valve and outlet valve.

Fig 1: Identifying Pressure Retaining Mode Diagram
G03661365Courtesy of AMERICAN HONDA MOTOR CO., INC.