Mode Control Motor Test
NOTE:
Before testing, check for HVAC DTCs (see GENERAL TROUBLESHOOTING INFORMATION
).
- Disconnect the 5P connector from the mode control motor.NOTE: Incorrectly applying power and ground to the mode control motor will damage it. Follow the instructions carefully.
- Connect battery power to the No. 1 terminal of the mode control motor, and ground the No. 2 terminal; the mode control motor should run smoothly, and stop at Vent. If it doesn't, reverse the connections; the mode control motor should run smoothly, and stop at Defrost. When the mode control motor stops running, disconnect battery power immediately.
- If the mode control motor did not run in step 2, remove it, then check the mode control linkage and doors for smooth movement.
- If the linkage and doors move smoothly, replace the mode control motor (see MODE CONTROL MOTOR REPLACEMENT ).
- If the linkage or doors stick or bind, repair them as needed.