Pressure retaining mode

VSA NO valve open, VSA NC valve closed, inlet valve closed, outlet valve closed.

Caliper fluid is retained by the inlet valve and outlet valve.

Fig 1: Identifying Pressure Retaining Mode
G03641397Courtesy of AMERICAN HONDA MOTOR CO., INC.