Distribution of Hydraulic Pressure
As the engine turns, the ATF pump start operate. Automatic transmission fluid (ATF) is drawn through the ATF strainer (filter) and discharged into the hydraulic circuit. Then, ATF flowing from the ATF pump becomes line pressure that's regulated by the regulator valve. Torque converter pressure from the regulator valve enters the torque converter through the lock up shift valve, and it is discharged from the torque converter. The torque converter check valve prevents torque converter pressure from rising.
The PCM controls the shift solenoid valves ON and OFF. The shift solenoid valve intercepts line pressure from the ATF pump via the manual valve when the shift solenoid valve is OFF. When the shift solenoid valve is turned ON, line pressure changes to shift solenoid valve pressure at the shift solenoid valve, then the solenoid valve pressure flows to the shift valve. Applying shift solenoid pressure to the shift valves moves the position of the shift valve, and switches the port of the hydraulic circuit. The PCM also controls A/T clutch pressure control solenoid valves A, B, and C. The A/T clutch pressure control solenoid valves regulate hydraulic pressure, and apply the pressure to the clutches to engage smoothly. The clutches receive optimum clutch pressure which is regulated by the A/T clutch pressure control solenoid valves for comfortable driving and shifting under all conditions.
Hydraulic pressure at the port is as follows:
| PORT NO. | DESCRIPTION OF PRESSURE | PORT NO. | DESCRIPTION OF PRESSURE |
|---|---|---|---|
| 1 | LINE | SB | SHIFT SOLENOID VALVE B |
| 3 | LINE | SC | SHIFT SOLENOID VALVE C |
| 3' | LINE | SD | SHIFT SOLENOID VALVE D |
| 4 | LINE | SE | SHIFT SOLENOID VALVE E |
| 4' | LINE | 10 | 1ST CLUTCH |
| 4" | LINE | 20 | 2ND CLUTCH |
| 7 | LINE | 30 | 3RD CLUTCH |
| 1A | LINE or A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE A | 40 | 4TH CLUTCH |
| 1B | LINE | 50 | 5TH CLUTCH |
| 3A | LINE | 55 | A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE A |
| 3B | LINE | 55' | A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE A |
| 3C | LINE | 56 | A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE B |
| 5A | LINE | 57 | A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE C |
| 5B | LINE | 90 | TORQUE CONVERTER |
| 5C | LINE | 91 | TORQUE CONVERTER |
| 5D | LINE | 92 | TORQUE CONVERTER |
| 5E | LINE or A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE B | 93 | ATF COOLER |
| 5F | LINE or A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE A or B | 94 | TORQUE CONVERTER |
| 5G | A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE B | 95 | LUBRICATION |
| 5H | A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE C | 96 | TORQUE CONVERTER |
| 5J | A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE C | 97 | TORQUE CONVERTER |
| 5K | A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE C | 99 | SUCTION |
| 5L | A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE C | X | DRAIN |
| 5N | A/T CLUTCH PRESSURE CONTROL SOLENOID VALVE C | HX | HIGH POSITION DRAIN |
| SA | SHIFT SOLENOID VALVE A | AX | AIR DRAIN |