Hazard Warning Switch
Remove center trim panel. Disconnect hazard warning switch 10-pin connector. Push out hazard warning switch from center trim panel. With hazard switch in specified position, check continuity between switch terminals. See Fig 1 . If continuity is not as specified, replace hazard warning switch (or illumination bulb if continuity does not exist between terminals No. 5 and 6).