Removal & Installation
Variable Valve Timing Control (VTC) oil control solenoid valve is located at front of cylinder head.
- Disconnect 2-pin harness connector.
- Remove VTC oil control solenoid valve retaining bolt and remove valve.
- To install, reverse removal procedure and use NEW O-ring. Tighten valve to specification. See TORQUE SPECIFICATIONS .