Positive Crankcase Ventilation
WARNING: This page is about a different car, the 2004 Acura 3.5RL, 2003 Acura 3.5RL, 2003 Acura 3.2TL, and 2003 Acura 3.2CL. However, it is still accessible from the selected car via links, so may be relevant.
Ensure crankcase ventilation hoses and connections are not clogged and no leaks exist. Start engine. With engine at idle, pinch and release PCV hose. PCV valve should click. If PCV valve does not click, check PCV valve grommet for cracks or damage. Ensure manifold vacuum exists at valve. If manifold vacuum is present and grommet is okay, replace PCV valve and recheck. If manifold vacuum is not present, check for restricted vacuum port or PCV hose.