Float Test

  1. Make sure the fuel tank is less than half full.
  2. Remove the fuel fill cap to relieve the fuel tank pressure, then reinstall the cap.
  3. Remove the fuel hose joint protector. Disconnect the ORVR vapor recirculation hose, and connect a vacuum pump to the vapor recirculation hose.
    Fig 1: Identifying ORVR Vapor Recirculation Hose
    G06290351Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Plug the hose port.
  5. Apply vacuum to the ORVR vapor recirculation hose.