Radiator Fan Control Module
Testing must be performed with radiator fan control module 8-pin connector connected, ignition on and A/C switch in OFF position. See RADIATOR FAN CONTROL MODULE INPUT TESTS
table. If cause of problem is discovered while performing tests, correct problem before continuing tests.
RADIATOR FAN CONTROL MODULE INPUT TESTS
| Pin No.(Wire Color) |
Test Condition |
Desired Results |
| 1(Yellow) |
Check For Battery Voltage |
Battery Voltage |
| 2(Yellow/Black) . |
Check For Battery Voltage |
Battery Voltage |
| 3(Yellow/White) |
. Check For Battery Voltage |
Battery Voltage |
| 4(Black) |
Check For Voltage To Ground |
Less Than 1 Volt |
| 5(Orange) |
Check For Battery |
Approximately 11 Volts |
| 6(White/Green) . |
Check For Battery Voltage |
Battery Voltage |
| 7(Black/Yellow) . |
Check For Battery Voltage |
Battery Voltage |
| 8(Light Green/Yellow) . |
Connected To Body Ground . |
Condenser Fan & Radiator Fan Run |