LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 1998 >> 3.0CL >> Repair and Diagnosis (Single Page) >> Electrical >> Gauges >> Instrument Panels >> System Testing >> Safety Indicator Unit Input Test

Safety Indicator Unit Input Test

Disable air bag system. See appropriate AIR BAG RESTRAINT SYSTEMS article in the ACCESSORIES/SAFETY EQUIPMENT section. Remove instrument cluster from instrument panel. See INSTRUMENT CLUSTER  under REMOVAL & INSTALLATION. Disconnect instrument cluster 22-pin "B" connector. Check for bent, corroded, loose or disconnected terminals in connector. Repair connectors as necessary and recheck system. See WIRING DIAGRAMS  . If all safety indicator input tests are okay, replace instrument cluster printed circuit board. See Fig 1 .

Fig 1: Safety Indicator Unit Input Testing
G97A11395Courtesy of AMERICAN HONDA MOTOR CO., INC.