Bleeding Cooling System
Always bleed air from cooling system after replacing coolant. Set heater for maximum heat. Remove radiator cap. Loosen drain plug and remove drain bolt (if equipped) from engine block. Drain coolant reservoir. Fill coolant reservoir to MAX mark with 50/50 water-coolant mixture. Loosen bleed bolt and fill radiator up to base of filler neck. Close bleed bolt when coolant flows out without bubbles. Tighten bleed bolt to 89 INCH lbs. (10 N.m). With radiator cap removed, start and run engine until normal operating temperature is reached. Top off coolant if necessary.