LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 1992 >> Integra GS-R >> Repair and Diagnosis >> Engine Mechanical >> Mechanical >> 1.7L 4-CYL >> Removal & Installation >> Bleeding Cooling System

Bleeding Cooling System

  1. To bleed air from cooling system, set heater controls to maximum heat. Loosen bleed bolt located on thermostat housing. Fill cooling system with a 50/50 mixture of coolant and water to bottom of filler neck.
  2. Tighten bleed bolt when coolant flows from bleed bolt in steady stream without bubbles. With radiator cap off, start engine, and operate it to normal operating temperature. Add coolant as necessary. Install radiator cap.