Function Control Motor
Connect battery voltage to terminal No. 5 of function control motor. Ground terminal No. 1. See Figure . Using jumper wire, connect terminal No. 1 to terminals No. 2, 3, 4, 7 and 8 in order. Motor should run each time connection is made. If motor operation is not as specified, replace function control motor.