LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 1990 >> Integra LS, 2D Hatchback, Standard >> Repair and Diagnosis >> Electrical >> Starter >> On-Vehicle Testing >> Cranking Test

Cranking Test

Connect a voltmeter and ammeter to battery. See Fig 1. Disconnect 2-pin connector from distributor. Check cranking voltage and current draw. Ensure voltage is at least 8 volts. Current draw should be less than 350 amps. Cranking speed should be above 100 RPM.

Fig 1: Connecting Voltmeter & Ammeter for Cranking Test
G29428Courtesy of AMERICAN HONDA MOTOR CO., INC.