Checking The Wiring And Component
Check the cable between the control module terminal #A45 and knock sensor (KS) terminal 3. Check for a short-circuit to ground according to Short-circuit to ground, permanent faults .
Check the cable between the control module terminal #A64 and knock sensor (KS) terminal 4. Check for a short-circuit to ground according to Short-circuit to ground, permanent faults .
Remedy as necessary.
Other information:
- To localize the knock sensor (KS), see Location of components
- To connect the breakout box, see Connecting the breakout box
- For information about signals, see Signal specification
Was a fault found in the wiring?
- YES
Refer to Verification
- NO
Refer to Replacing knock sensor